Comparative Analysis of The Efficacy of Upper Lip Bite Test and Thyromental Distance for Prediction of Difficult Intubation

Authors

  • Muhammad Abdul Sattar Department of Health Professional Technologies, Faculty of Allied Health Sciences, The University of Lahore, Lahore, Pakistan Author
  • Abdul Wadood Department of Health Professional Technologies, Faculty of Allied Health Sciences, The University of Lahore, Lahore, Pakistan Author
  • Fatima Noreen Lecturer, Department of Health Professional Technologies, The University of Lahore, Lahore, Pakistan Author
  • Awais Akhtar Lecturer, Department of Health Professional Technologies, The University of Lahore, Lahore, Pakistan Author
  • Inam Ullah Department of Health Professional Technologies, Faculty of Allied Health Sciences, The University of Lahore, Lahore, Pakistan Author

DOI:

https://doi.org/10.61919/8w26p934

Keywords:

Difficult intubation; Airway management; Upper Lip Bite Test; Thyromental Distance; Diagnostic accuracy; Preoperative assessment

Abstract

Background: Unanticipated difficult intubation remains a major contributor to perioperative morbidity and mortality, underscoring the need for reliable bedside airway assessment tools. The Upper Lip Bite Test (ULBT) and Thyromental Distance (TMD) are commonly used preoperative predictors, yet their comparative diagnostic performance remains clinically debated. Objective: To compare the diagnostic accuracy of ULBT and TMD in predicting difficult intubation among adult patients undergoing elective surgery under general anesthesia. Methods: In this comparative cross-sectional observational study, 119 adult patients scheduled for elective surgery requiring endotracheal intubation were consecutively enrolled. Preoperative airway assessment included ULBT and TMD classification using standardized criteria. Difficult intubation was defined as Cormack–Lehane grade III/IV or intubation requiring more than three attempts or prolonged duration. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), likelihood ratios, and accuracy were calculated with 95% confidence intervals. Results: Difficult intubation occurred in 21 patients (17.7%). ULBT demonstrated higher sensitivity than TMD (66.7% vs 47.6%) with comparable specificity (87.8% vs 89.8%). ULBT showed superior NPV (92.5% vs 88.9%) and lower negative likelihood ratio (0.38 vs 0.58), indicating improved rule-out capability, while PPV was moderate for both tests (53.8% vs 50.0%). Conclusion: ULBT provides greater sensitivity and stronger exclusion performance compared with TMD, supporting its preferential use as a primary bedside screening tool within a multimodal airway assessment strategy.

Downloads

Published

2026-02-15

Data Availability Statement

All the data is available

Issue

Section

Articles

How to Cite

1.
Muhammad Abdul Sattar, Abdul Wadood, Fatima Noreen, Awais Akhtar, Inam Ullah. Comparative Analysis of The Efficacy of Upper Lip Bite Test and Thyromental Distance for Prediction of Difficult Intubation. JHWCR [Internet]. 2026 Feb. 15 [cited 2026 Feb. 28];4(3):e1271. Available from: https://www.jhwcr.com/index.php/jhwcr/article/view/1271

Most read articles by the same author(s)

1 2 3 > >>